Wait a second...
Nepřihlášený uživatel
iduzel: 27484
idvazba: 35028
šablona: stranka
čas: 19.4.2024 16:06:50
verze: 5378
uzivatel:
remoteAPIs:
branch: trunk
Server: 147.33.89.150
Obnovit | RAW
iduzel: 27484
idvazba: 35028
---Nová url--- (newurl_...)
domena: 'clab.vscht.cz'
jazyk: 'en'
url: '/rtg-en/equipment'
iduzel: 27484
path: 1/20076/20078/20082/27383/27484
CMS: Odkaz na newurlCMS
branch: trunk
Obnovit | RAW

Laboratory of X-ray Diffractometry and Spectrometry

XRD - diffractometer PANanalytical Empyrean

(PANanalytical, Holland)

diffractometer Empyrean, PC controlled, Cu tube, goniometr, PC for data collection and evaluation with yearly updated database PDF-4+, PDF-4/Organics.Standard Bragg-Brentano set-up for XRD analysis - automatic variable slits, sample changer for 45 samples, 1D detector PIXCEL. Measurement range 0.6-140° - „beam knife“.Set-up for measurement of thin layers with thickness below 200nm – focusing mirror, parallel plate collimator 0.18degree + sealed 0D detektor.

More details: https://www.malvernpanalytical.com/en/products/product-range/empyrean-range/empyrean

 ◳ rtg (jpg) → (ořez 215*215px)

High temperature chamber for X-Ray diffractometer (XRD)

High temperature chamber HTK1200n (Anton Paar) is available for the X-Ray diffractometer PANalytical Empyrean. High temperature limit is 1200 dgC.
For more details see: 

XRD - diffractometer Bruker AXS D8

(Bruker, Germany)

diffractometer Bruker D8, PC controlled, Co(Cu or Mo tube), goniometr, automatic variable slits, rotational sample stage, sample changer for 7 samples,   1D LynxEye detector, yearly updated database PDF-4+, PDF-4/Organics, high

šířka 450px

XRD - diffractometer PANanalytical X´Pert PRO

(PANanalytical, Holland)

diffractometer X´Pert PRO, PC controlled, Co tube, goniometr,  automatic variable slits, sample changer for 15 samples, 1D XCelerator detector, yearly updated database PDF-4+, PDF-4/Organics. Measurement range 0.6-140° - „beam knife“.

šířka 450px

XRD - diffractometer PANanalytical X'Pert3 Powder

(PANanalytical, Holland)

diffractometer X´Pert3 Powder, PC controlled, Cu tube, goniometr, automatic variable slits, sample changer for 15 samples, 1D detector PIXCEL, yearly updated database PDF-4+, PDF-4/Organics. Measurement range 0.6-140° - „beam knife“.

šířka 450px

microXRD – microdiffraction and texture system D8 Discover with the 2D Vantech detector

(Bruker, Germany)

Microdiffraction system D8 Discover, PCr controlled, Co tube, goniometr, parallel polycapilary optic POLYCAP with primary diametr beam of 4mm, 5 long UBC collimators – diameters 0.1, 0.3, 0.5, 1 and 2mm. Compact motorized XYZ stage – load capacity 1kg, maximum height of sample 42mm, X,Y,Z –range -25mm. X-ray powder diffraction can be employed with the aim to measure powder patterns from spots of a minimum size 100 x 100 μm. The system is capable to collect Debye-Scherrer frames convertible into a standard 1D powder pattern.

šířka 450px

XRF - spectrometer ARL 9400 XP

(Thermo ARL, Switzerland)

Fully automatic sequantial XRF spectrometer for qualitative and quantitative element analysis up to 83 elements of periodic table (B-C O-U) in the range from ppm to 100%. Possible samples – solid materials, powders, thin films and fluids. Rh tube, 4kW generator, 4 collimators, 6 crystals (AX 20, TLAP, PET, Ge 111, LiF 200, LiF 220), 2 detectors  – proporcional and scintilation.   Analysis using calibration curve done with software Winxrf. Standardless analysis done with program Uniquant 4.

šířka 215px

XRF - spectrometer Axios

(PANanalytical, Holland)

Fully automatic sequantial XRF spectrometer for qualitative and quantitative element analysis up to 87 elements of periodic table (B-U) in the range from ppm to 100%. Possible samples – solid materials, powders, thin films and fluids. Rh tube, 4kW generator, 3 collimators, 8 crystals (PX1, PX4a, PX5, PX7, PE002, Ge 111, LiF 200, LiF 220), 2 detectors  – proporcional and scintilation.   Analysis using calibration curve done with software SuperQ 5.0. Standardless analysis done with program Omnian.

šířka 215px

• XRF - spectrometer Performix – spot analysis(1.5mm) and mapping – circle with diameter 20mm

(Thermo ARL, Switzerland)

Fully automatic sequantial XRF spectrometer for qualitative and quantitative element analysis up to 83 elements of periodic table(Be-B O-U) in the range from ppm to 100%. Possible samples – solid materials, powders, thin films and fluids. Rh tube, 4kW generator, 4 collimators, 6 crystals (AXBeB, AX03, PET, Ge 111, LiF 200, LiF 220), 2 detectors  – proporcional and scintilation.   Analysis using calibration curve done with software Oxsas. Standardless analysis done with program Uniquant 5 integrated in Oxsas. Spot analysis from the 1.5mm spot.

šířka 215px

XRF - spectrometr ZSX Primus IV (Rigaku, Japonsko)

Fully automatic sequantial XRF spectrometer for qualitative, semiquantitative and quantitative element analysis up to 87 elements of periodic table (Be-U) in the range from ppm to 100%. Possible samples – solid materials, powders, thin films and fluids. Rh tube ABOVE SAMPLE=well pressed samples can be mesured without binder or foil (B-Mg measured easily and more accurately), 4kW generator, 3 collimators, 7 crystals (RX85-Be-B, RX61-C, RX40-N-O, RX26-F-Na-Mg, PET, Ge 111, LiF 200), 2 detectors – proporcional and scintilation. SEMIQUANTITATIVE standardless analysis performed with program SQX, QUANTITATIVE analysis using calibration curve performed with software SQX. More info: https://www.rigaku.com/products/wdxrf/primusiv

 ◳ ZSX Primus (jpg) → (šířka 450px)

EDXRF portable spectrometr XL5

(Thermo)

is a device for for a qualitative, semiquantitative and quantitative element analysis in an elemental  range Mg-U  and in a concentration range 0.01-100%, time 120s(chemical composition, shape and size of the sample are important).

XL5 can perform fast screening of present elements in concentration above 0.1% in time of 30s.

Measured spot is the circle with the diameter of 8mm, possibility to use mask with diameter of 3mm, worse detection limits and longer time.

Sample is measured in air and in principle may have whatever dimensions. It is possible to measure small samples( better not smaller than 3mm) or larger samples (X-ray safe are samples which fit in standard desk stand, Maxsize D19xW19xH11cm). Bigger saples can be measured if the safety rules are fulfilled.

Available calibrations Mining(8mm), General Metals (3,8mm), Coating (8mm), Plastics (8mm), Soils(8mm).

 

http://www.hukos.cz/spektrometr-xl5/

https://www.thermofisher.com/order/catalog/product/NITONXL5

Updated: 28.7.2023 11:15, Author: Jan Prchal


UCT Prague
Technická 5
166 28 Prague 6 – Dejvice
IČO: 60461373 / VAT: CZ60461373

Czech Post certified digital mail code: sp4j9ch

Copyright: UCT Prague 2015
Information provided by the Department of International Relations and the Department of R&D. Technical support by the Computing Centre.
switch to full version